Product

CMPA 2020C MPO/PLC test system

CMPA 2020C MPO/PLC test system
CMPA 2020C MPO/PLC test system

CMPA 2020C MPO/PLC test system

Technique Data

  1. Wavelength(nm):                     1310/1550                        8501300

  2. Stability (dB):                           0.01                                  0.01

  3. Channels(dB):                         12/24/36/48/64                 12/24/36/48/64

  4. Linear (dB):                             0.04dB (+3~-40dBm)        0.3dB (-40~-60dBm)

  5. Optical Input Range (dBm):   +5- 60

  6. Test uncertainty:                      5%

  7. RL Range(dB):                      >75                                    >50

  8. RL test uncertainty:                 0.3 dB (0~-60dB)    1.0 dB (-60~-75dB)    0.3 dB (0~-45dB)    1.0 dB (-45~-55dB) 

  9. Test repeatability:                    0.02

  10. Control interface:                     RS232 / Ethernet

  11. Power Supply:                         110VAC/220VAC 50HZ

  12. Working temperature ():     -10~+40

  13. Storage temperature ():      -25~+70

  14. Dimension(mm):                      300x340x160

  1. MPO/MTP test system

  2. 12/24/36/48/64 MPO,MTP test

  3. Optional PDL module , PLC splitter test

  4. Dual connector test